All our products can be ordered online directly from TUNGUS Corporation here  

 

 

Contact our Sales team or call (613) 854-0081 (Eng) or (343) 549-9468 (Fr) for a detailed assessment of your fire protection requirements and the recommended type of extinguishing module, triggering sensor and mounting brackets.

 

 

 

 

 

 

 

 

 

 

Product Categories

 

 

 

 

 

 

 

 

 

 

 

STAND-ALONE MODULES :

 

 

 

 

Stand-alone modules are single modules of different sizes. The actual size of the module for each particular application is determined by the assessed size of the location of the potential fire hazard and the different options for installation.

Complete installation requires also at least one of the triggering sensors, fire-resistant wire, mounting bracket(s) and the recommended size and type of hardware.

Such stand-alone modules are generally installed and visible on a ceiling, sloped ceiling, wall, beam, joist, post or any similar structure.

 

 

 

 

Ceiling & Wall Mounted

These types of modules are either used for protection of the specific spot of a potential fire hazard and/or for general protection of an overall area or room, as may be required

 

 

 

 

Portable & Handheld

These modules are used for applications where portable or temporary protection is required for the spot of a potential fire hazard or for general protection of an overall area or room

 

 

 

 

Floor, Wall & Ceiling Mounted

These high capacity modules with extreme coverage are suitable for protection for potentially larger fire hazards or for general protection of an larger overall area or room

Installation of these types of modules requires custom made brackets due to the high powered recoil during discharge.

 

 

 

 

 

 

 

 

 

DO-IT-YOURSELF INSTALLATION KITS :

 

 

 

 

These kits are ready for Do-It-Yourself installation and come in different sizes. Each kit contains one MPP extinguishing module pre-wired with a USP-101 triggering sensor. Complete installation requires additional mounting bracket(s) based on type of installation - vertical, horizontal or sloped/angled.

Such stand-alone modules are generally installed and visible on a ceiling, sloped ceiling, wall, beam, joist, post or any similar structure.

 

 

 

 

MPP 0.65 (N) Kit

 

 

 

 

 

 

 

 

 

MPP 2.0 (N) Kit

 

 

 

 

 

 

 

 

 

MPP 2.7 (N) Kit

 

 

 

 

 

 

 

 

 

MPP 4.0 (N) Kit

 

 

 

 

 

 

 

 

 

MPP 5.0 (N) Kit

 

 

 

 

 

 

 

 

 

MPP 5.0 R - Ready-to-use Kit

 

 

 

 

 

 

 

 

 

MPP 6.0 (N) Kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSIDE-CEILING INSTALLATION KITS :

 

 

 

 

Complete kits, containing special brackets with a pre-installed MPP module, pre-wired with USP-101 triggering sensor, ready for DIY installation inside a drywalled ceiling.

Installation is completely hidden inside the ceiling with only the white bottom (3mm thick) plate of the bracket visible.

 

 

 

 

MPP 2.0 slide-in Kit

Mountable between 12 or 16 spaced joists. Can be used for protection of a kitchen stove, wooden stove or fireplace, laundry room.

 

 

 

 

MPP 2.7 slide-in Kit

Mountable between 12or 16spaced joists. Similar use as above, with larger discharge load for better protection of similar sized fire hazard spots but in larger rooms.

 

 

 

 

MPP 4.0 slide-in Kit

Mountable between 16 spaced joists and suitable for protection of a large kitchen, living room area with fireplace or wooden stove, bedrooms.

 

 

 

 

 

 

 

 

INDIVIDUAL MOUNTING BRACKETS :

 

 

 

 

Different types of mounting brackets, or combination of brackets, are required for different types of installation - horizontal ceiling, sloped ceiling, horizontal beam, joists, vertical wall, post.

Any installation must be on a strong, immovable, rigid surface such as concrete, brick, metal or strong wooden structure.

 

 

 

 

 

TCB-10 Base

Required as the base bracket for installation on a sloped ceiling or other angled application

 

 

 

TCB-20 Side

Required as the base for vertical installation on a wall, post or joist

 

 

 

TCB-30-1 for MPP 2.0

Used alone strictly for vertical installation on a ceiling or horizontal installation on a wall, post or joist

Used in combination with TCB-10 for installation on a sloped ceiling or angled application

Used in combination with TCB-20 for vertical installation on a wall, post or joist  

 

 

 

TCB-30-2 for MPP 2.7; 5.0

Used alone strictly for vertical installation on a ceiling or horizontal installation on a wall, post or joist

Used in combination with TCB-10 for installation on a sloped ceiling or angled application

Used in combination with TCB-20 for vertical installation on a wall, post or joist 

 

 

 

TCB-30-3 for MPP 4.0; 6.0; 9.0

Used alone strictly for vertical installation on a ceiling or horizontal installation on a wall, post or joist

Used in combination with TCB-10 for installation on a sloped ceiling or angled application

Used in combination with TCB-20 for vertical installation on a wall, post or joist

 

 

 

 

 

 

 

 

 

 

 

 

HEAT DETECTING & TRIGGERING SENSORS :

 

 

 

 

 

 

 

 

Sensors are used to detect a rise in heat within the protected area and to trigger the MPP module discharge. All sensors can also be connected to an existing fire alarm panel, security system or simple visual and/or audio device such as a siren and flashing lights to provide an alert that a fire incident has occured, the MPP module has been discharged, and further attention is required.

 

 

 

 

USP-101 (45C; 72C; 93C; 110C)

Single-level heat detecting / triggering sensor, no batteries, no electricity required

 

 

 

USPAA-1 V2

Dual-level temperature triggering/signalling sensor, requiring one CR2032 battery (battery lasts about 2 years in stand-by mode) 

 

 

 

 

USPAA-1 V4

Dual-level temperature triggering/signaling sensor with optical flame recognition, requiring two AA batteries (batteries lasts about one year in stand-by mode)

 

 

 

 

USPAA-1 V5 - COMING SOON !

Enhanced  version of USPAA-1 V4 with an internal battery guaranteed by the manufacturer to last 10 years in standby mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

Module Variations (temperature range)

 

 

 

 

 

 

For special applications under extreme conditions, all TUNGUS modules are manufactured in a variety of temperature resistance levels, including high and low extremes. Generally, the Standard version N is sufficient for any day-to-day use. The NT and NT-1 versions should be used in applications requiring specifically high temperature resistance.

 

 

 

 

 

 

STANDARD version (N)

operating temperature ranges from -50C up to +50C

 

COLD/HEAT RESISTANT version (NT)

operating temperature ranges from -60C up to +90C

 

EXTREME COLD/HEAT RESISTANT version (NT-1)

operating temperature ranges from -60C up to +125C

 

VEHICULAR version (N-A-T-1)

operating temperature ranges from -60C up to +125C, vibration and corrosion resistant, designed specifically for protection of engine and hydraulic compartments of buses, trucks, harvester combines, locomotives, heavy machinery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<